dc.descriptionEsta tesis además de una introducción a nuevas tecnologías de generación eléctrica como lo son los Generadores Termoeléctricos de estado sólido o Modulos Peltier, es un análisis experimental para determinar el comportamiento de un modulo termoeléctrico peltier comercial, como generador termoeléctrico, principalmente el análisis de este trabajo se enfoca en el funcionamiento del modulo termoeléctrico y su eficiencia pero eliminando elementos como el ventilador, ya que este crea una mayor diferencia de temperatura, además de consumir potencial. También se desarrollo un banco de pruebas el cual puede ser usado con cualquier otro modulo termoeléctrico, este banco contiene una fuente de calor (resistencia eléctrica regulada). Se midieron los voltajes de salida del modulo termoeléctrico y se obtuvieron sus termografías en cada prueba para así observar las diferencias de temperatura a cada extremo del modulo termoeléctrico. Con estos resultados se analizaron las irreversibilidades por medio de un modelo matemático, y se obtuvo la eficiencia neta del modulo termoeléctrico, ya que generalmente el fabricante nos proporciona datos usando ventilación forzada ya que así se eleva la eficiencia del generador termoeléctrico.es
dc.description.abstractIn this work, besides being an introduction to new technologies such as thermoelectric generators, solid state, or Peltier modules, is an experimental analysis to determine the behavior of a commercial Peltier thermoelectric module as a thermoelectric generator, the analysis in this paper , focuses on the thermoelectric module performance and efficiency. But deleting items like fans, that creates a greater temperature differential and spending potential. Constructed a test bed, which can be used with any other thermoelectric module, it contains a heat source (electric resistance regulated). We measured the output voltages of thermoelectric module thermograms were taken in each test, to detect temperature differences at the ends of the thermoelectric module. With these results, we analyzed the irreversibility’s using a mathematical model, and obtained the net efficiency of the thermoelectric module, because the manufacturer usually provides data using forced ventilation by increasing the efficiency of the thermoelectric generator.es
dc.language.isoeses
dc.subjectGENERADOR PELTIERes
dc.subjectPROCESOS IRREVERSIBLESes
dc.subjectANÁLISIS EXPERIMENTALes
dc.titleANÁLISIS EXPERIMENTAL DE UN GENERADOR PELTIER Y SUS PROCESOS IRREVERSIBLESes
dc.typeThesises
dc.description.especialidadMaestría en Ciencias de Ingeniería en Sistemas Energéticoses